Read Command

Sets the style of the Read BRI command sent to the RFID reader. Values for Read Command are READ REPORT=DIRECT, READ REPORT=NO, READ REPORT=EVENT, and User-Defined Read Command.

READ REPORT=DIRECT enables single-shot read mode. Each trigger pull immediately gathers data from all of the tags within range of the RFID reader.

READ REPORT=NO enables continuous read mode. The reader collects tag information asynchronously but does not report the tag list, which is viewed at a later time. The tag list is populated internally with each trigger pull. When the trigger is released, the collected tag data is sent to your host computer.

READ REPORT=EVENT enables continuous mode and reports tags after a timeout has expired. Tag data is collected every 800 milliseconds.

User- Defined reader command enables the User-defined Read Command field, allowing the user to enter a custom READ command.

Default Setting

READ REPORT = DIRECT

READ REPORT = EVENT (CV31)

Command Location

Virtual Wedge > RFID Reader Wedge > Read Command